HDD/SSD Burn-in Equipment

This is the equipment in which a burn-in test of HDD or SSD is implemented.

<Support Interfaces>

  • SATA III
  • SATA II
  • SATA I
  • SAS I
  • SAS II(Option)

Application

HDD and SSD Product Evaluation
HDD and SSD Reliability Evaluation

Features

The maximum 192 pcs of devices can be tested at the same time.
The wide range of operating temperature(Ambient Temperature ~+75℃)
Supportive Drive’s interface are up to SATA III / SAS II(Option)
Drive’s power supply is available in 2 lines(5V, 12V)
Independent control and measurement of voltage/current can be implemented every port and line.
The synchronized test of temperature control/interface can be implemented.
The same scripts and application softwares of SMART TESTER for 6G can be applicable.
The equipped LEDs at port can indicate the test status and result.
Capable of supporting DEVSLP
Capable of customization of number of Ports, temperature range, etc.

Model

H192PB SATA25-6G-D

Specifications

Name Burn-in Test Equipment for 6Gbps
Model Type H192PB SATA25-6G-D
Chamber Outer Dimensions 970mm(W)×1250mm(D)×1910mm(H) ※excluding the maximum protrusion
Installation Space 2370mm(W)×2950mm(D)×2000mm(H)
Equipment Body Weight(kg) 700kg
Operating Temperature Ambient Temperature: 22℃~28℃, Ambient Humidity: 20~80%RH ※No condensation shall exist.
Equipment Power Supply and Current Consumption 3 phase AC200V±10%, 50/60Hz
Current Consumption: 40A
Utility -
Safety Mechanism Preventive Excessive Temperature Rise Mechanism
Emergency Stop Button
Preventive Automatic Restoration Function After Emergency Stop or Power Outage
Number of Test Drives Maximum 192 Drives
Test Drive Type Type: SATA and SAS I/F HDD and SSD
Support I/F: SATA III, SATA II, SATA I, SAS I, SAS II(Option)
Permissible Heat Generation: 2.5W
Temperature and Humidity Control Range (Ambient Temperature +10℃) ~ +75℃
Temperature Accuracy within ±3℃(at steady state)
Humidity Accuracy -
Applied Voltage to Drive 12.0V line Output Voltage: 8.0V~14.5V 20mV
Step Variation Voltage Accuracy: Setup Voltage±100mV
Load Current: 3.5mA max.
3.3V line Output Voltage: Setup Voltage±100mV
Step Variation Voltage Accuracy: Setup Voltage±50mV
Load Current: 4.2A max
Drive's Power Voltage Measurement 12.0V line 0.0V~15.0V Measurement Accuracy±3%F.S. Resolution: approx. 7.9mV
3.3V line 0.0V~5.0V Measurement Accuracy±3%F.S. Resolution: approx. 3.5mV
Measurement Interval 125μsec~200msec interval(125μsec Step) Maximum 65520 samples
Drive's Power Current Measurement 12.0V line 0.0A~4.0A Measurement Accuracy±3%F.S. Resolution: approx. 2.0mA
3.3V line 0.0A~5.0A Measurement Accuracy±3%F.S. Resolution: approx. 2.6mA
Measurement Interval 125μsec~200msec interval(125μsec Step) Maximum 65520 samples

Above specifications may change without notice.